TECNOWARE

UPS 1200VA/840W Line-Interactive, Tower, 2x Schuko

FGCERAPL1202SCH

Novi proizvod

Dobavljivo 9 kom kod dobavljača

Isporuka: 3 - 5 radnih dana

Vaša prava iz zakonskog jamstva

Uplata na račun

81,13 €s PDV-omCijena na 10.9.2026.: 81,13 €

Plaćanje karticama

89,24 €

Cijena na 10.9.2026.: 89,24 €
12 × 7,44 € 6 × 14,87 € 3 × 29,75 €

Okvirna cijena po ratama karticama, s PDV-om

Isporuka: 3 - 5 radnih dana

Besplatno preuzimanje u Zagrebu: Mail Boxes Etc., Radnička cesta 20

Dodaj u listu želja

  • Diners Club International
  • Discover
  • Dinacard
  • WSPay
  • Google Pay
  • Visa
  • Mastercard
  • Maestro
  • Diners
  • Discover
  • DinaCard
  • KEKS Pay
  • PayPal
  • Google Pay
  • Bitcoin

Specifikacije

Width
10.10 cm
Height
14.20 cm
Depth
27.90 cm
Battery type
Lead acid, sealed, maintenance free
Type of execution
Tower
Main Input Voltage
230 V
Main Output Voltage
230 V
Rated power in W
840 W
Rated power in VA
1200 VA
Input Connection Type
Schuko
Output Connection Type
2 Schuko
net. Weight
4.50 kg
Network frequency
50/60 Hz (automatic selection)
Input voltage limits
+20%/-25%
Maximum configurable power in VA
1200 VA
Maximum configurable power in W
840 W
Output frequency
50/60 Hz (automatic selection)
Wave type
Modified sinewave
Transfer time
2 ms typical
Standards
IEC 62040-1-1, IEC 62040-2, IEC 62040-3
Ambient air temperature for operation
0..55 °C
Relative humidity
0…95 %
Operating altitude
0...3000 m
Acoustic level
40 dBA
Colour
Black
IP protection
IP20
Backup time
10-40 min
Input Frequency Range
+/- 5%
Fiscalization 2.0 Article
G46.50.22

Opis

Maximum computer power*
1200 VA/840 W

Technologies
Line Interactive with stabilizer

Interface
USB port

Cooling
Natural

Audible noise
< 40 dBA at a distance of 1 m

Dimensions (UPS) WxHxD
10.1x14.2x27.9 cm

Dimensions (with packaging) WxHxD
18x22x34 cm

Weight
4.5 kg

Number of phases
1F+N

The rated voltage is single-phase
230 V AC

Input voltage range
+20%/-25%

Rated frequency
50/60 Hz (automatic selection)

Input frequency range
+/- 5%

Number of phases
1F+N

Rated voltage Single-phase
230 V AC

Voltage regulation (Line mode)
AVR (Automatic voltage regulation)

Voltage regulation (battery mode)
+/- 5%

Frequency
50/60 Hz (automatic selection)

The signal form of the inverter
Modified sine wave

The possibility of overload
< 130 %

Transfer time
2 ms (typical)


Lead-acid type, sealed, maintenance-free

Backup time (typical)
10-40 min.

Operating temperature
From 0 to 55 °C (recommended from 20 to 25 °C)

Humidity
< 95% non-condensing

Maximum height
3000 m

IP protection
IP20

Recenzije

Trenutno nema recenzija korisnika.

Napiši osvrt

UPS 1200VA/840W Line-Interactive, Tower, 2x Schuko