UPS 2400VA/2160W On-Line Double Conversion, Rack/Tower, Sinewave, 8xC13

FGCEDP2402RTIEC

Novi proizvod

3 - 5 radnih dana

2 god.

Količina: 2 raspoloživa (kod dobavljača)

Cijena za gotovinu (uplatu na račun):

576,13 € s PDV-om

Cijena za kartice:

633,74 € s PDV-om

Okvirna cijena po ratama:
12 * 52,81 € s PDV-om
6 * 105,62 € s PDV-om
3 * 211,25 € s PDV-om

Dodaj u listu želja

  • Diners Club International
  • Discover
  • Dinacard
  • WSPay
  • Google Pay

Podaci

Battery type Lead-acid battery
Type of execution Rackmount / Tower
Main Input Voltage 230 V
Main Output Voltage 230 V
Rated power in W 2.16 kW
Rated power in VA 2.4 kVA
Product or component type Uninterruptible power supply (UPS)
Provided equipment User manual
Redundant No
Network frequency 50/60 Hz
Input voltage limits 110...300 V
Maximum configurable power in VA 2400 VA
Maximum configurable power in W 2160 W
Output frequency 50/60 Hz (selectable)
UPS type Double conversion online
Wave type Sine wave
Transfer time 0 ms
Product certifications CE
Standards Low Voltage Directive IEC EN 62040-1 EMC Directive IEC EN 62040-2 classification IEC EN 62040-3
Ambient air temperature for operation 0..55 °C
Relative humidity 0…95 %
Operating altitude 0...3000 m
Storage Relative Humidity 0…95 %
Storage altitude 0…3000 m

Više informacija

UPS EVO DSP PLUS 2,400 RACK TOWER - Power 2,400 VA PF 0,9. On Line Technology (VFI) DSP, Efficiency 94%, Input / output 230 / 230Vac 50 / 60Hz, 8 IEC C13 sockets, dimensions 43.8x8.8x41 cm (2U), weight 19 Kg, bacup time 10 min, including 4 batteries of 12Vdc 9Ah. Positioning in 19" rack or tower, multifunction graphic LCD display, static bypass, hot swap battery, EPO connector for USB and RS232 communication ports for UPS control and on / off programming via the free TecnoManager software. SNMP or Dry Contact card (optional).

Complete protection from blackout, voltage fluctuations (overvoltages and undervoltages), lightning (with upstream arrester), frequency variations, surges, harmonics, voltage distortions

Recommended for Data Centers, Local Area Network (LAN ), Electro-medical, Industry processes, Virtual servers, Pellet stoves, Thermo-fireplaces, Boilers for home heating

Convertible format (Rack 19" or Tower) with adjustable display

Hot Swap batteries

Intelligent slot for SNMP card o Dry Contact

On-Line Double Conversion technology transformerless (VFI-SS-111)

Active PFC circuit (0.99)

Compatibility with generating set

Battery charging system managed by microprocessor

Static bypass